EPS 20mA Series EMC & LVD Tested Models |
20mA |
Features:
- Electronic type neon power supply;
- Environment friendly, RoHS compliant;
- Measuring up to latest CE standard;
- High power factor and low electromagnetic disturbance;
- Earth-leakage protection;
- Open circuit protection;
- Fully sealed and waterproof;
- No mercury migration or "jelly-bean" effect; |
Environmental Specifications :
- Operating temperature: -25℃~+40℃;
- Cooling: Convection;
- Relative humidity: 5% to 100%;
- Installation: Indoor or Outdoor; |
Certificates & Standards :
- TüV-CE
- TüV-EMC: EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3;
- TüV-LVD: EN 61347-2-10, EN 61347-1;
- SGS-RoHS: 2002/95/EC;
|
EPS-3000-20 |
|
Model |
EPS-3000-20 |
|
Size
LXWXH(mm) |
150*29*27 |
|
Weight(kg) |
0.2 |
|
Input |
220-240VAC
50/60Hz 0.1A |
|
Power |
23 W |
|
Output |
3000V
AC 20mA |
|
Power factor |
PF>0.9, THD<25% |
|
Working frequency |
45KHz |
|
Over-load protection |
Yes |
|
Open-circuit protection |
Yes |
|
Earth-leakage protection |
Yes |
|
Protection degree |
IP 65 |
|
Input cable |
0.3m |
|
Input plug |
Optional |
|
Input switch |
Optional (switch on cord) |
|
Ouput cable |
0.6m |
|
Ext. dimming control app. |
Yes |
|
Ext. flashing control app. |
Yes |
|
Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
4 |
4 |
5 |
5 |
6 |
8 |
8 |
10 |
|
4 |
4 |
5 |
6 |
7 |
9 |
10 |
12 |
|
1.2 |
1.2 |
1.5 |
1.5 |
1.8 |
2.4 |
2.4 |
3 |
|
1.2 |
1.2 |
1.5 |
1.8 |
2.1 |
2.7 |
3 |
3.6 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
Load
length(m)Clear/Neon |
|
Load
length(m)Mercury/Argon |
|
EPS-6000-20
|
|
Model |
EPS-6000-20 |
|
Size
LXWXH(mm) |
151*63.5*38 |
|
Weight(kg) |
0.67 |
|
Input |
220-240VAC
50/60Hz 0.3A |
|
Power |
69 W |
|
Output |
6000V
AC 20mA |
|
Power factor |
PF>0.9, THD<25% |
|
Working frequency |
35KHz |
|
Over-load protection |
Yes |
|
Open-circuit protection |
Yes |
|
Earth-leakage protection |
Yes |
|
Protection degree |
IP 65 |
|
Input cable |
0.5m |
|
Input plug |
Optional |
|
Input switch |
Optional (switch on cord) |
|
Ouput cable |
0.6m |
|
Ext. dimming control app. |
Yes |
|
Ext. flashing control app. |
Yes |
|
Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
11 |
12 |
14 |
17 |
20 |
23 |
25 |
30 |
|
12 |
14 |
16 |
20 |
24 |
27 |
30 |
36 |
|
3.3 |
3.6 |
4.2 |
5.1 |
6 |
6.9 |
7.5 |
9 |
|
3.6 |
4.2 |
4.8 |
6 |
7.2 |
8.1 |
9 |
11 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
Load
length(m)Clear/Neon |
|
Load
length(m)Mercury/Argon |
|
EPS-8000-20
|
|
Model |
EPS-8000-20 |
|
Size
LXWXH(mm) |
200*70*50 |
|
Weight(kg) |
1.1 |
|
Input |
220-240VAC
50/60Hz 0.4A |
|
Power |
92 W |
|
Output |
8000V
AC 20mA |
|
Power factor |
PF>0.9, THD<25% |
|
Working frequency |
25KHz |
|
Over-load protection |
Yes |
|
Open-circuit protection |
Yes |
|
Earth-leakage protection |
Yes |
|
Protection degree |
IP 65 |
|
Input cable |
0.5m |
|
Input plug |
Optional |
|
Input switch |
Optional (switch on cord) |
|
Ouput cable |
0.6m |
|
Ext. dimming control app. |
Yes |
|
Ext. flashing control app. |
Yes |
|
Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
15 |
16 |
18 |
21 |
26 |
30 |
33 |
40 |
|
17 |
18 |
20 |
26 |
30 |
34 |
40 |
47 |
|
4.5 |
4.8 |
5.4 |
6.3 |
7.8 |
9 |
10 |
12 |
|
5.1 |
5.4 |
6 |
7.8 |
9 |
10 |
12 |
14 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
Load
length(m)Clear/Neon |
|
Load
length(m)Mercury/Argon |
|
|
EPS-10000-20 |
|
Model |
EPS-10000-20 |
|
Size
LXWXH(mm) |
244*65.5*45 |
|
Weight(kg) |
1.2 |
|
Input |
220-240VAC
50/60Hz 0.5A |
|
Power |
115 W |
|
Output |
10000V
AC 20mA |
|
Power factor |
PF>0.9, THD<25% |
|
Working frequency |
25KHz |
|
Over-load protection |
Yes |
|
Open-circuit protection |
Yes |
|
Earth-leakage protection |
Yes |
|
Protection degree |
IP 65 |
|
Input cable |
0.5m |
|
Input plug |
Optional |
|
Input switch |
Optional (switch on cord) |
|
Ouput cable |
0.6m |
|
Ext. dimming control app. |
Yes |
|
Ext. flashing control app. |
Yes |
|
Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
16 |
18 |
21 |
25 |
30 |
35 |
39 |
45 |
|
18 |
21 |
25 |
30 |
36 |
42 |
46 |
55 |
|
4.8 |
5.4 |
6.3 |
7.5 |
9 |
11 |
12 |
14 |
|
5.4 |
6.3 |
7.5 |
9 |
11 |
12 |
14 |
16 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
Load
length(m)Clear/Neon |
|
Load
length(m)Mercury/Argon |
|
Notes:
- Deduct 1ft(0.3m) for each pair of electrodes from above load
length figures.
- Max. load length may vary according to HV wire lead length
and environment.
- Footage for mercury filled tubes based on operation at 4℃
(40 )
or above, deduct 25% of footage for operation below 4℃ (40
). |
|
|