Our Products:   Our Mission
" To serve the needs of our clients in gaining a competitive
  Advantage by harnessing technology."
  Neon Power Supply
  Me-120 UL 2161 Series
  NPS-120 UL 506 Series
  NPS-n220 CE Series
  EPS 20mA CE Series
  XPS 40mA CE Series
  NP AC Series
  NP DC Series
  NP 3KV Series
  XP Series
  EP Series
  Built-in Dimmer,Flasher...
  Magnetic Neon Transformer
  NT Series
  NT UL 2161 Series
  ENT Series
  Electrode
  Neon Tube Electrode
 Cold Cathode Tube Electrode
  Neon Tubing
  PML Lead Glass Series
  CG Series
  Neon Accessories
  Vacuum System
  Rare Gases
  HT Cable
  Electrode Cover
  Neon Tube Support
  Neon Testing Tools
  Miscellaneous
  LED
  LED Module
  SPS LED Power Supply
  LPS LED Power Supply
  Electronic Ballast
  EBO HO Sign Ballast
  EBC Commercial Ballast
  Neon & LED Signs
EPS 20mA Series EMC & LVD Tested Models 20mA
Features:
- Electronic type neon power supply;
- Environment friendly, RoHS compliant;
- Measuring up to latest CE standard;
- High power factor and low electromagnetic disturbance;
- Earth-leakage protection;
- Open circuit protection;
- Fully sealed and waterproof;
- No mercury migration or "jelly-bean" effect;
Environmental Specifications :
- Operating temperature: -25℃~+40℃;
- Cooling: Convection;
- Relative humidity: 5% to 100%;
- Installation: Indoor or Outdoor;
Certificates & Standards :
- TüV-CE
- TüV-EMC: EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3;
- TüV-LVD: EN 61347-2-10, EN 61347-1;
- SGS-RoHS: 2002/95/EC;
EPS-3000-20
  Model   EPS-3000-20
  Size LXWXH(mm)   150*29*27
  Weight(kg)   0.2
  Input   220-240VAC 50/60Hz 0.1A
  Power   23 W
  Output   3000V AC 20mA
  Power factor   PF>0.9, THD<25%
  Working frequency   45KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  Protection degree   IP 65
  Input cable   0.3m
  Input plug   Optional
  Input switch   Optional (switch on cord)
  Ouput cable   0.6m
  Ext. dimming control app.   Yes
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
4 4 5 5 6 8 8 10
4 4 5 6 7 9 10 12
1.2 1.2 1.5 1.5 1.8 2.4 2.4 3
1.2 1.2 1.5 1.8 2.1 2.7 3 3.6
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Load length(m)Clear/Neon
  Load length(m)Mercury/Argon
EPS-6000-20
  Model   EPS-6000-20
  Size LXWXH(mm)   151*63.5*38
  Weight(kg)   0.67
  Input   220-240VAC 50/60Hz 0.3A
  Power   69 W
  Output   6000V AC 20mA
  Power factor   PF>0.9, THD<25%
  Working frequency   35KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  Protection degree   IP 65
  Input cable   0.5m
  Input plug   Optional
  Input switch   Optional (switch on cord)
  Ouput cable   0.6m
  Ext. dimming control app.   Yes
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
11 12 14 17 20 23 25 30
12 14 16 20 24 27 30 36
3.3 3.6 4.2 5.1 6 6.9 7.5 9
3.6 4.2 4.8 6 7.2 8.1 9 11
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Load length(m)Clear/Neon
  Load length(m)Mercury/Argon
EPS-8000-20
  Model   EPS-8000-20
  Size LXWXH(mm)   200*70*50
  Weight(kg)   1.1
  Input   220-240VAC 50/60Hz 0.4A
  Power   92 W
  Output   8000V AC 20mA
  Power factor   PF>0.9, THD<25%
  Working frequency   25KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  Protection degree   IP 65
  Input cable   0.5m
  Input plug   Optional
  Input switch   Optional (switch on cord)
  Ouput cable   0.6m
  Ext. dimming control app.   Yes
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
15 16 18 21 26 30 33 40
17 18 20 26 30 34 40 47
4.5 4.8 5.4 6.3 7.8 9 10 12
5.1 5.4 6 7.8 9 10 12 14
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Load length(m)Clear/Neon
  Load length(m)Mercury/Argon

EPS-10000-20

  Model   EPS-10000-20
  Size LXWXH(mm)   244*65.5*45
  Weight(kg)   1.2
  Input   220-240VAC 50/60Hz 0.5A
  Power   115 W
  Output   10000V AC 20mA
  Power factor   PF>0.9, THD<25%
  Working frequency   25KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  Protection degree   IP 65
  Input cable   0.5m
  Input plug   Optional
  Input switch   Optional (switch on cord)
  Ouput cable   0.6m
  Ext. dimming control app.   Yes
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
16 18 21 25 30 35 39 45
18 21 25 30 36 42 46 55
4.8 5.4 6.3 7.5 9 11 12 14
5.4 6.3 7.5 9 11 12 14 16
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Load length(m)Clear/Neon
  Load length(m)Mercury/Argon
Notes:
- Deduct 1ft(0.3m) for each pair of electrodes from above load length figures.
- Max. load length may vary according to HV wire lead length and environment.
- Footage for mercury filled tubes based on operation at 4℃ (40) or above, deduct 25% of footage for operation below 4℃ (40 ).
Next Series

EPS  20mA Series