| EP Series-------------High Voltage A.C. Output Model |
Features:
- Electronic type neon power supply
- Compact size and light weight
- No gas tubes discoloration or no mercury migration, perfect for mercury tubes
- Safe and reliable with built-in open circuit protection and thermal protection
- Completely sealed and waterproof |
Environmental Specifications :
- Operating temperature: -25℃~+40℃
- Cooling: Convection
- Relative humidity: 5% to 100%
- Installation: Indoor or Outdoor |
Certificates & Standards :
- GB19510 |
|
|
| Model |
EP-7500-30 |
| Size
LXWXH(mm) |
135*56*39 |
| Weight(kg) |
0.39 |
| Input |
230VAC
50/60Hz 0.3A |
|
Power |
69 W |
|
Output |
7500V
AC 30mA |
|
Power factor |
PF>0.9, THD<25% |
|
Working frequency |
34-37KHz |
|
Over-load protection |
Yes |
|
Open-circuit protection |
Yes |
|
Earth-leakage protection |
N/A |
|
Protection degree |
IP 65 |
|
Input cable |
0.5m |
|
Input plug |
Optional |
|
Input switch |
No |
|
Ouput cable |
0.6m |
|
Ext. dimming control app. |
Yes |
|
Ext. flashing control app. |
Yes |
|
Loading Length Data Sheet |
| Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
20 |
22 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
8 |
7.5 |
7 |
|
11 |
12 |
14 |
17 |
20 |
23 |
25 |
30 |
36 |
39 |
43 |
|
12 |
14 |
16 |
20 |
24 |
27 |
30 |
36 |
40 |
45 |
50 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
|
|
| Model |
EP-10000-30 |
| Size
LXWXH(mm) |
160*62*43 |
| Weight(kg) |
0.58 |
| Input |
230VAC
50/60Hz 0.4A |
|
Power |
92 W |
|
Output |
10000V
AC 30mA |
|
Power factor |
PF>0.9, THD<30% |
|
Working frequency |
21-24KHz |
|
Over-load protection |
Yes |
|
Open-circuit protection |
Yes |
|
Earth-leakage protection |
N/A |
|
Protection degree |
IP 65 |
|
Input cable |
0.5m |
|
Input plug |
Optional |
|
Input switch |
No |
|
Ouput cable |
0.6m |
|
Ext. dimming control app. |
Yes |
|
Ext. flashing control app. |
Yes |
|
Loading Length Data Sheet |
| Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
20 |
22 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
8 |
7.5 |
7 |
|
15 |
16 |
18 |
21 |
26 |
30 |
33 |
40 |
47 |
55 |
62 |
|
17 |
18 |
20 |
26 |
30 |
34 |
40 |
47 |
55 |
62 |
68 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
Notes:
- Deduct 1 ft for each pair of electrodes from above load length
figures.
- Max. length in ft may vary according to HV wire lead length
and environment.
- Footage for mercury filled tubes based on operation at 4℃
(40 )
or above, deduct 25% of footage for operation below 4℃ (40
). |
|
|