| NT UL 2161 Series - 120V Neon Transformer |
 |
Features:
- Traditional coil and core transformer
- Compact size and light weight
- Resin filled and vacuum potted
- High reliability and long life
|
Environmental Specifications :
- Operating temperature: -25℃~+40℃
- Cooling: Convection
- Relative humidity: 5% to 95%
- Installation: Indoor or Outdoor |
NT120B7530 |
|
MODEL |
NT120B7530 |
|
SIZE
LXWXH(mm) |
320x103x105 |
|
WEIGHT(kg) |
/ |
|
INPUT |
120V AC/60Hz 2.30A |
| OUTPUT |
7500V 30mA |
| Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
9 |
10 |
11 |
12 |
13 |
14 |
15 |
18 |
|
15 |
13 |
12 |
11 |
10 |
10 |
9 |
8 |
|
15 |
17 |
19 |
21 |
22 |
24 |
26 |
28 |
| 18 |
20 |
23 |
25 |
27 |
28 |
31 |
35 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
NT120B0930 |
|
MODEL |
NT120B0930 |
|
SIZE
LXWXH(mm) |
320x103x105 |
|
WEIGHT(kg) |
/ |
|
INPUT |
120V AC/60Hz 2.80A |
| OUTPUT |
9000V 30mA |
| Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
9 |
10 |
11 |
12 |
13 |
14 |
15 |
18 |
|
15 |
13 |
12 |
11 |
10 |
10 |
9 |
8 |
|
18 |
21 |
24 |
26 |
29 |
30 |
33 |
40 |
| 22 |
25 |
26 |
31 |
33 |
36 |
40 |
45 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
NT120B1230 |
|
MODEL |
NT120B1230 |
|
SIZE
LXWXH(mm) |
365x120x145 |
|
WEIGHT(kg) |
11.7 |
|
INPUT |
120V AC/60Hz 3.40A |
| OUTPUT |
12000V 30mA |
| Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
9 |
10 |
11 |
12 |
13 |
14 |
15 |
18 |
|
15 |
13 |
12 |
11 |
10 |
10 |
9 |
8 |
|
26 |
29 |
32 |
35 |
39 |
42 |
45 |
55 |
| 31 |
35 |
38 |
42 |
46 |
50 |
55 |
62 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
NT120B1530 |
|
MODEL |
NT120B1530 |
|
SIZE
LXWXH(mm) |
365x120x145 |
|
WEIGHT(kg) |
13.3 |
|
INPUT |
120V 60Hz 3.90A |
| OUTPUT |
15000V 30mA |
| Loading Length Data Sheet |
|
Diameter
Tubing(mm) |
|
9 |
10 |
11 |
12 |
13 |
14 |
15 |
18 |
|
15 |
13 |
12 |
11 |
10 |
10 |
9 |
8 |
|
32 |
36 |
40 |
45 |
50 |
54 |
60 |
72 |
| 39 |
44 |
48 |
54 |
60 |
64 |
72 |
80 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
|
|
|
NT UL 2161 Series ---- 120V Neon Transformer |