XPS
40mA Series EMC & LVD Tested Models |
40mA |
Features:
- Output current
is 40mA, suitable for Cold Cathode Lighting or neon tube >Dia. 12mm.
- High power factor and low electromagnetic disturbance
measuring up to EMC standards.
- Output over voltage protection.
- Fully sealed and waterproof,good for both
indoor and outdoor use.
- No mercury migration or " jelly-bean" effects.
- Special arranged GTO cables from two sides, reduce the
chance of arcing, sparking and high-voltage cross-over etc. |
Environmental Specifications :
- Operating temperature: -25℃ ~ +40℃
- Cooling:Convection
- Relative humidity:5% to 100%
- Installation:Indoor or Outdoor |
Certificates & Standards :
- CE-EMC:EN 55015; EN 61547; EN 61000-3-2; EN 61000-3-3
- CE-LVD:EN 61347-2-10; EN 61347-1 |
XPS-6000-40 |
|
Model |
XPS-6000-40 |
|
SIZE
LXWXH(mm) |
252*57*39 |
|
Packing |
20 pcs; G.W.:18kg; 0.04m³ |
|
Input |
220-240VAC
50/60Hz 0.6A |
| Power |
144W |
|
Output |
3000-E-3000V
35/50mA(norm) |
| Power factor |
PF>0.92, THD≤38% |
| Working frequency |
37-40KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
Yes |
| IP Rating |
IP66 |
| Input cable |
0.5m |
| Input plug |
optional |
| Input switch |
No |
| Output cable |
0.5m |
| Ext.dimming control app. |
No |
| Ext.flashing control app. |
Yes |
|
Diameter
Tubing(mm) |
|
12 |
13 |
15 |
18 |
20 |
|
11 |
10 |
9 |
8 |
7 |
|
18 |
19 |
23 |
25 |
28 |
|
21 |
23 |
28 |
30 |
32 |
|
5.4 |
5.7 |
6.9 |
7.5 |
8.4 |
|
6.3 |
6.9 |
8.4 |
9.0 |
9.6 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
Load
length(m)Clear/Neon |
|
Load
length(m)Mercury/Argon |
|
XPS-8000-40 |
|
MODEL |
XPS-8000-40 |
|
SIZE
LXWXH(mm) |
289*67*46 |
|
Packing |
10 pcs; G.W.: 14kg; 0.03m³ |
|
Input |
220-240VAC
50/60Hz 0.8A |
| Power |
192W |
|
Output |
4000V-E-4000V 35/50mA |
| Power factor |
PF>0.92, THD≤38% |
| Working frequency |
25-28KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
N/A |
| IP Rating |
IP66 |
| Input cable |
0.5m |
| Input plug |
optional |
| Input switch |
No |
| Output cable |
0.5m |
| Ext.dimming control app. |
No |
| Ext.flashing control app. |
Yes |
|
Diameter
Tubing(mm) |
|
12 |
13 |
15 |
18 |
20 |
|
11 |
10 |
9 |
8 |
7 |
|
23 |
25 |
31 |
33 |
35 |
|
26 |
31 |
36 |
38 |
41 |
|
6.9 |
7.5 |
9.3 |
9.9 |
10.5 |
|
7.8 |
9.3 |
10.8 |
11.4 |
12.3 |
|
|
Gas
Pressure(mmHg) |
|
Load
length(ft.)Clear/Neon |
|
Load
length(ft.)Mercury/Argon |
|
Load
length(m)Clear/Neon |
|
Load
length(m)Mercury/Argon |
|
Notes:
- The above max. loading length figures are for reference only, the actual loading capability may vary due to different installation way or environmental factors(see User Guide for more information). Electrodes are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- Length figures for mercury filled tubes are based on operation in temperatures above 4℃
(40 ) .It's recommended to deduct 25% from the figuress for operation below 4℃
(40 ) |
|
|