Features:
-
Maximum output current is 40mA, suitable for neon application
with higher current and brightness requirement.
- Input circuit contains no electrolysis capacitance, thus causing
no starting surge. Suitable for large flashing units, scanning
control units, dimming control units, continuous-operating units.
- Built- in open circuit protection,
thermal protection and external surge protector. |
Environmental Specifications :
- Operating temperature: -25℃ ~ +40℃
- Cooling: Convection
- Relative humidity: 5% to 100%
- Installation: Indoor or Outdoor |
Certificates & Standards :
- GB19510 |
 |
| Model |
XP-7500-40 |
| Size
LXWXH(mm) |
252*57*39 |
| Weight(kg) |
0.9 |
| Input |
220-240VAC
50/60Hz 600mA |
| Power |
144W |
| Output |
7.5kV
AC 40mA |
| Power factor |
PF>0.9, THD<38% |
| Working frequency |
37-40KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
N/A |
| IP Rating |
IP 66 |
| Input cable |
0.35m |
| Input plug |
No |
| Input switch |
No |
| Output cable |
0.5m |
| Ext.dimming control app. |
No |
| Ext.flashing control app. |
Yes |
| Diameter
Tubing(mm) |
| 12 |
13 |
15 |
18 |
20 |
| 11 |
10 |
9 |
8 |
7 |
| 23 |
26 |
30 |
36 |
39 |
| 26 |
30 |
36 |
39 |
46 |
| 7 |
8 |
9 |
11 |
12 |
| 8 |
9 |
11 |
12 |
14 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
| Load
length(m)Clear/Neon |
| Load
length(m)Mercury/Argon |
|
 |
| Model |
XP-10000-40 |
| Size
LXWXH(mm) |
288*67*45 |
| Weight(kg) |
1.4 |
| Input |
220-240VAC
50/60Hz 800mA |
| Power |
192W |
| Output |
10kV
AC 40mA |
| Power factor |
PF>0.9, THD<38% |
| Working frequency |
26-28KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
N/A |
| IP Rating |
IP 66 |
| Input cable |
0.35m |
| Input plug |
No |
| Input switch |
No |
| Output cable |
0.5m |
| Ext.dimming control app. |
No |
| Ext.flashing control app. |
Yes |
| Diameter
Tubing(mm) |
| 12 |
13 |
15 |
18 |
20 |
| 11 |
10 |
9 |
8 |
7 |
| 30 |
33 |
39 |
46 |
56 |
| 33 |
39 |
46 |
56 |
62 |
| 9 |
10 |
12 |
14 |
17 |
| 10 |
12 |
14 |
17 |
19 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
| Load
length(m)Clear/Neon |
| Load
length(m)Mercury/Argon |
|
Notes:
- The above max. loading length figures are for reference only, the actual loading capability may vary due to different installation way or environmental factors(see User Guide for more information). Electrodes are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- Length figures for mercury filled tubes are based on operation in temperatures above 4℃
(40 ) .It's recommended to deduct 25% from the figuress for operation below 4℃
(40 ) |
|
|
|
XP Series ---- Extra High Voltage High Frequency Output Models |