Measuring up to the requirements of UL/CSA standards for neon
transformers.
- High power factor and low harmonic distortion.
- Built-in automatic overload protection circuit.
- With pull-chain switch and UL/CSA standard plug, easy to install, most suitable for small neon signs.
- No mercury migration or 'Jelly-bean' effects. |
| MODEL |
NPS-120-6000-30 |
| SIZE
LXWXH(mm) |
159*57*42 |
| WEIGHT(kg) |
0.60 |
| INPUT |
120VAC
60Hz 0.5A |
| OUTPUT |
5kV 30mA |
| Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
7 |
8 |
9 |
11 |
13 |
16 |
17 |
19 |
|
8 |
9 |
11 |
12 |
15 |
18 |
20 |
23 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
|
|
| MODEL |
NPS-120-9000-30 |
| SIZE
LXWXH(mm) |
132*76*46 |
| WEIGHT(kg) |
0.70 |
| INPUT |
120VAC
60Hz 0.75A |
| OUTPUT |
6.5kV 30mA |
| Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
12 |
13 |
15 |
19 |
22 |
26 |
29 |
33 |
|
14 |
15 |
18 |
23 |
26 |
31 |
33 |
40 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
Notes:
- Deduct 1 foot for each pair of electrodes from above load
length figures.
- Maximum length in feet may vary according to HV wire lead
length and environment.
- Footage for mercury filled tubes are based on operation in
temperatures above 4℃(40 ).
deduct 25% of footage for operation below 4℃(40 ). |
| MODEL |
NPS-120-12000-30 |
| SIZE
LXWXH(mm) |
176*94*47 |
| WEIGHT(kg) |
1.09 |
| INPUT |
120VAC
60Hz 0.8A |
| OUTPUT |
9kV 30mA |
| Diameter
Tubing(mm) |
|
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
|
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
|
16 |
18 |
21 |
25 |
30 |
35 |
39 |
45 |
|
18 |
21 |
25 |
30 |
36 |
42 |
46 |
55 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
|
|