| --- Dimming Switch Optional |
|
Features:
- UL 2161 standard.
- Ground-fault protection.
- Open circuit protection.
- No mercury migration or "jelly-bean" effect.
- Optional with built-in dimming switch. |
Environmental Specifications :
- Operating temperature: -25℃~+40℃
- Cooling: Convection
- Indoor type 7 for dry or damp location |
Certificates & Standards :
- UL 2161 |
 |
| Model |
Me-120-3000-30 |
| Size
LXWXH(mm) |
120*44*30 |
| Weight(kg) |
0.3 |
| Input |
120VAC
50/60Hz 0.5A |
| Power |
36W |
| Output |
3kV 30mA |
| Power factor |
PF>0.9,THD<45% |
| Working frequency |
40-41KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
Yes |
| IP Rating |
Indoor type 7 |
| Input cable |
2m |
| Input plug |
Yes |
| Input switch |
Switch on the cord |
| Output cable |
0.6m |
| Ext. dimming control app. |
No |
| Ext. flashing control app. |
Yes |
| Loading Length Data Sheet |
| Diameter
Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
3 |
3 |
4 |
4 |
5 |
6 |
6 |
8 |
3 |
3 |
4 |
5 |
5 |
7 |
8 |
9 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
 |
| Model |
Me-120-6000-30 |
| Size
LXWXH(mm) |
147*67*43 |
| Weight(kg) |
0.60 |
| Input |
120VAC
50/60Hz 0.5A |
| Power |
60W |
| Output |
5kV 30mA |
| Power factor |
PF>0.9,THD<45% |
| Working frequency |
38-40KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
Yes |
| IP Rating |
Indoor type 7 |
| Input cable |
2m |
| Input plug |
Yes |
| Input switch |
Pull chain switch |
| Output cable |
0.8m |
| Ext. dimming control app. |
No |
| Ext. flashing control app. |
Yes |
| Loading Length Data Sheet |
| Diameter
Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
5 |
6 |
7 |
8 |
10 |
12 |
13 |
14 |
6 |
7 |
8 |
9 |
11 |
14 |
15 |
18 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
 |
| Model |
Me-120-9000-30 |
| Size
LXWXH(mm) |
147*67*43 |
| Weight(kg) |
0.60 |
| Input |
120VAC
50/60Hz 0.75A |
| Power |
90W |
| Output |
6.5kV 30mA |
| Power factor |
PF>0.9,THD<45% |
| Working frequency |
36-38KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
Yes |
| IP Rating |
Indoor type 7 |
| Input cable |
2m |
| Input plug |
Yes |
| Input switch |
Pull chain switch |
| Output cable |
0.8m |
| Ext. dimming control app. |
No |
| Ext. flashing control app. |
Yes |
| Loading Length Data Sheet |
| Diameter
Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
9 |
10 |
11 |
14 |
17 |
20 |
22 |
25 |
11 |
11 |
14 |
18 |
20 |
24 |
25 |
31 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
 |
| Model |
Me-120-12000-30 |
| Size
LXWXH(mm) |
176*94*47 |
| Weight(kg) |
1.00 |
| Input |
120VAC
50/60Hz 0.9A |
| Power |
108W |
| Output |
8kV 30mA |
| Power factor |
PF>0.9,THD<45% |
| Working frequency |
23-25KHz |
| Over-load protection |
Yes |
| Open-circuit protection |
Yes |
| Earth-leakage protection |
Yes |
| IP Rating |
Indoor type 7 |
| Input cable |
2m |
| Input plug |
Yes |
| Input switch |
Pull chain switch |
| Output cable |
0.8m |
| Ext. dimming control app. |
No |
| Ext. flashing control app. |
Yes |
| Loading Length Data Sheet |
| Diameter
Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
12 |
14 |
16 |
19 |
23 |
27 |
30 |
34 |
14 |
16 |
19 |
23 |
27 |
32 |
35 |
42 |
|
| Gas
Pressure(mmHg) |
| Load
length(ft.)Clear/Neon |
| Load
length(ft.)Mercury/Argon |
|
Notes:
- The above max. loading length figures are for reference only, the actual loading capability may vary due to different installation way or environmental factors(see User Guide for more information). Electrodes are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- length figures for mercury filled tubes are based on operation in temperatures above 4℃(40 ).
Deduct 25% from the figures for operation below 4℃(40 ) |
|
|